background image

PNEG-823 Deluxe Downwind Heater

15

5. Bin Configuration

Figure 5A

IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as in

above

Figure 5A

. Plenum thermostat must be to the right of master heater and master heater

must be to the right of slave heater.

Operating Temperature Table

IMPORTANT: Do not exceed plenum temperatures listed in table.

This table is not intended as a drying guide. It should be used as a reference for setting maximum
plenum temperature for safe operation.

Low-Temperature Batch

High-Temperature

Batch Dry No Stirring

High-Temperature

with Stirring

Continuous Flow

(Recirculating)

Corn

5°-20° Above Ambient Temp.

120°

140°

160°

Rice

5°-10° Above Ambient Temp.

100°

100°

Not Recommended

Beans and Wheat 5°-20° Above Ambient Temp.

110°

120°

Not Recommended