PNEG-823 Deluxe Downwind Heater
15
5. Bin Configuration
Figure 5A
IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as in
. Plenum thermostat must be to the right of master heater and master heater
must be to the right of slave heater.
Operating Temperature Table
IMPORTANT: Do not exceed plenum temperatures listed in table.
This table is not intended as a drying guide. It should be used as a reference for setting maximum
plenum temperature for safe operation.
Low-Temperature Batch
High-Temperature
Batch Dry No Stirring
High-Temperature
with Stirring
Continuous Flow
(Recirculating)
Corn
5°-20° Above Ambient Temp.
120°
140°
160°
Rice
5°-10° Above Ambient Temp.
100°
100°
Not Recommended
Beans and Wheat 5°-20° Above Ambient Temp.
110°
120°
Not Recommended