8. Operating Procedure

PNEG-823 Deluxe Downwind Heater 23

20 HP-40 HP Units BTUs per Gauge Pressure (PSI) Propane
Models (Approximate)

High-Temperature 20 HP-40 HP 5/16" (0.313") Orifice

Operating Pressure (PSI)

Gauge Pressure (PSI) Required to Maintain Temperature (Approximate)

(20 HP-40 HP High-Temperature Propane Units Only)

2

4

6

8

10

12

14

15

All Models

1663135

2345140

2878779

3328663

3721115

4068100

4393548

4541914

Fan Model

Static Pressure

Heat Rise (°F)

60

80

100

120

140

160

180

20 HP

2"

2

2

4

5

7

8

10

4"

1

2

3

4

5

7

8

6"

1

2

3

4

5

6

7

25 HP

2"

2

3

5

7

9

12

15

4"

2

3

4

6

8

10

13

6"

2

2

4

5

6

8

10

30 HP

2"

2

4

6

8

11

15

4"

2

4

5

7

10

13

6"

2

3

4

6

8

10

13

40 HP

2"

3

6

8

12

4"

3

5

7

11

14

6"

3

4

7

9

12

Advertising