Chapter 7: roof assembly – Grain Systems Tanks PNEG-4054G User Manual
Page 121

Figure 7-35 Installing the cap plates
I
Long center collar channel (CTR-0153)
N
3/8 x 1 in. bolt with sealing washer (S-7487)
J
Splice plate (CTR-0164)
O
Vendor lifting eyebolt
K
Tube caulk
P
3/8 in. nut (S-456)
L
Side cap plate (CTR-0162), approximately
56 lb (25.4 kg)
Q
Center cap plate (CTR-0163), approximately 125
lb (56.7 kg)
M
3/8 x 1 in. bolt with sealing washer (S-
7487)
22.Place a continuous bead of tube caulk (V) on the mating surface of the roof flashing.
NOTE: Before continuing, read and understand the safe and proper lifting procedures needed to
install the A-frames. For more information, see
Guidelines for Assembling and Lifting the A-
Frame Rafter Sections, page 103
23.Attach the appropriate lifting chains (R) to the previously installed lifting eyebolts.
Pneg-4054G 54 Ft Diameter 40-Series Bin
121