10. Electrical Load Information

26

PNEG-338 Portable Dryer Installation and Towing

1218

1 PH 230V

Top Auger

5

26

286

178

400

100

Bottom Auger

5

26

100

Top Fan

10 to 17

78

100

Bottom Fan

10 to 12

48

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

5

13.2

183

98.4

225

60

Bottom Auger

5

13.2

60

Top Fan

15

39

60

Bottom Fan

10 to 12

33

60

(2) Auxiliary

(2) 10

52

*

3 PH 440V

Top Auger

5

6.6

96

49.2

150

60

Bottom Auger

5

6.6

60

Top Fan

15

19.5

60

Bottom Fan

10 to 12

16.5

60

(2) Auxiliary

(2) 10

26

*

1220

1 PH 230V

Top Auger

7.5

31

298

188

400

100

Bottom Auger

7.5

31

100

Top Fan

10 to 17

78

100

Bottom Fan

10 to 12

48

100

(2) Auxiliary

(2) 7.5

62

*

3 PH 220V

Top Auger

7.5

20

229

112

300

90

Bottom Auger

7.5

20

90

Top Fan

15

39

60

Bottom Fan

10 to12

33

60

(2) Auxiliary

(2) 15

78

*

3 PH 440V

Top Auger

7.5

10

123

59

200

60

Bottom Auger

7.5

10

60

Top Fan

15

19.5

60

Bottom Fan

10 to 12

16.5

60

(2) Auxiliary

(2) 15

39

*

1222

3 PH 220V

Top Auger

7.5

20

241

123

350

90

Bottom Auger

7.5

20

90

Top Fan

20

50

90

Bottom Fan

10 to 12

33

60

(2) Auxiliary

(2) 15

78

*

3 PH 440V

Top Auger

7.5

10

129

64.5

200

60

Bottom Auger

7.5

10

60

Top Fan

20

25

60

Bottom Fan

10 to 12

16.5

60

(2) Auxiliary

(2) 15

39

*

1226

3 PH 220V

Top Auger

10

26

271

149

350

90

Bottom Auger

10

26

90

Top Fan

25

64

90

Bottom Fan

10 to 12

33

60

(2) Auxiliary

(2) 15

78

*

3 PH 440V

Top Auger

10

13

144

77.5

200

60

Bottom Auger

10

13

60

Top Fan

25

32

60

Bottom Fan

10 to 12

16.5

60

(2) Auxiliary

(2) 15

39

*

*Auxiliaries run through load and unload breakers.

Dryer

Model #

Voltage

Motor

HP

Fuel Load

Amps

Maximum Amps

with Auxiliaries

Minimum

Amps

Recommended

Service in Amps

Branch Breaker

in Amps