Inspection sections – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-681 User Manual
Page 16

6. Boot Section
16
PNEG-681 Series II Bucket Elevator
Inspection Sections
The inspection section of the GSI Bucket Elevator has been designed for easy installation
and maintenance.
1. The removable panels can be installed in any order, to allow for the installation of inspection doors
at any preferred locations.
NOTE: Typical installations often place the inspection section directly above the boot on the up-leg side
as the first trunking section.
NOTE: Installation will vary and depend on the configuration and application.
NOTE: Along with the inspection section, you will receive installation hardware and two (2) tie angles.
Units containing 42" diameter pulleys and larger, will include a cross tie on the legs, which will be
included.
Figure 6B Inspection Section