Stiffener Flashing Support Instructions for Internal Stiffeners

1. Install the floor and support system, cutting the floor to go around the internal stiffeners as required.

(See Figure 3G.)

2. Break the stiffener flashing support (SS-6984) into its three (3) components.

3. Lay the flashing supports on top of the flooring and weld the flashing supports to the stiffener as close

as possible. Fasten the flashing to the wall, flashing support and floor, seal all spaces by welding
or caulking.

4. Paint all welds with good quality zinc rich paint.

5. Stiffener flashing supports (SS-6984) must be ordered separately from the standard floor

and flashing.