6. Stiffeners

40

PNEG-4036 40 Series 33' and 36' Diameter Bins

Stiffeners Splice

Use the following information to determine the gauge of the splice needed to connect the stiffeners.

(See Figure 6C.)

Figure 6C Stiffener Splice

Use the following chart to determine the gauge of the splice, which is determined by the gauge of the
stiffeners that are being connected. If connecting a heavier gauge to a lighter gauge stiffener, always use
the heavier gauge splice for the 13 to 12, 8 to 6 and 2 to 0 gauge connections.

For example: If connecting a 13 gauge stiffener to a 12 gauge stiffener, use the 12 gauge splice. If
connecting an 8 gauge stiffener to a 6 gauge stiffener, use the 10 gauge splice. If connecting a 2 gauge
stiffener to a 0 gauge stiffener, use the 8 gauge splice.

Splice Usage

Ref #

Part #

Description

Length

Available Gauges

A

CTS–2091XX

Stiffener Splice

10" (25.4 cm)

8, 10, 12, 14

Stiffener Gauge

Splice Gauge

8 Gauge

10 Gauge

12 Gauge

14 Gauge

18

X

17

X

16

X

15

X

14

X

13

X

12

X

11

X

10

X

9

X

8

X

6

X

5

X

2

X

0

X