6. Stiffeners
40
PNEG-4036 40 Series 33' and 36' Diameter Bins
Stiffeners Splice
Use the following information to determine the gauge of the splice needed to connect the stiffeners.
Figure 6C Stiffener Splice
Use the following chart to determine the gauge of the splice, which is determined by the gauge of the
stiffeners that are being connected. If connecting a heavier gauge to a lighter gauge stiffener, always use
the heavier gauge splice for the 13 to 12, 8 to 6 and 2 to 0 gauge connections.
For example: If connecting a 13 gauge stiffener to a 12 gauge stiffener, use the 12 gauge splice. If
connecting an 8 gauge stiffener to a 6 gauge stiffener, use the 10 gauge splice. If connecting a 2 gauge
stiffener to a 0 gauge stiffener, use the 8 gauge splice.
Splice Usage
Ref #
Part #
Description
Length
Available Gauges
A
CTS–2091XX
Stiffener Splice
10" (25.4 cm)
8, 10, 12, 14
Stiffener Gauge
Splice Gauge
8 Gauge
10 Gauge
12 Gauge
14 Gauge
18
X
17
X
16
X
15
X
14
X
13
X
12
X
11
X
10
X
9
X
8
X
6
X
5
X
2
X
0