8. Instructions

72

PNEG-4036 40 Series 33' and 36' Diameter Bins

Auto-Vent Assembly and Installation Instructions

The following instructions are for assembling and installing the Auto-Vent. First, check the packing list to
ensure all components have been shipped. The unit is easiest assembled in the upside down position
as shown in the instructions.

Assembly

1. Take all parts out of the shipping box and check if all parts are present.

2. Turn one roof vent housing (MIS-6778) upside down.

(See Figure 8A.)

3. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through hole in the side of roof vent. Place

jamb nut onto the bolt and tighten.

(See Figure 8A.)

4. Slide flap assembly (MIS-6777) on to bolt. The bolt should slide through hole in the flap assembly

bracket. Install with curvature cupped upward and the brackets in the position as shown in

Figure 8A

.

5. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the other side of the roof vent, through

jamb nut and other flap assembly bracket. Tighten nut against vent housing side.

6. Apply a bead of tube caulking around three (3) housing sides of the roof vent where it meets the

hold-down angle.

7. Place hold-down angle (MIS-4404) on the assembled roof vent. The wide end of the hold-down angle

must face vent discharge. Once aligned, screw nine (9) #10 self-drilling (S-280) screws through the
roof housing and into the hold-down angle.

(See Figure 8B on Page 73.)

Figure 8A

Ref #

Part #

Description

A

MIS-6777

Flap Assembly

B

MIS-6778

Vent Housing Assembly