Date: 03-19-12

PNEG-1856

Instructions

1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421

PNEG-1856

Page 1 of 9

Printed in the U.S.A.
Copyright © 2012 by GSI Group
www.gsiag.com

CN-206548

Baldor Motor Kit

Programming Baldor H2 and VS Drives on Dryers Built 1993 and
Prior or 1998 and UP

For the purpose of making Baldor AC drives work with Zimmerman control panels some parameter
settings must be changed. Some parameters remain unchanged. When programming AC drive you must
change only parameters shown in chart

on Page 2

and skip those not shown.

Setting Procedure

1. Power up drive.

2. Press MENU key to display programming options.

3. Scroll, with up and down arrow keys, to programming and press ENTER key.

4. Scroll through top level programming menu using up and down arrow keys until setting to be

changed, determined by chart

on Page 2

, is reached.

5. Press ENTER key to program top level parameters. (Example: Level 1 blocks.)

6. Scroll through 1

st

level parameter group, using up and down arrow keys, finding the parameters to

be modified according to chart

on Page 2

.

7. Press ENTER at selected 1

st

level parameters to get to individual parameters.

8. Scroll through individual parameters, using up and down arrow keys, finding the parameters to be

modified according to chart

on Page 2

.

9. Modify factory settings of the individual parameters shown in the chart

on Page 2

. To do so:

a. Press ENTER key to begin value change.

b. If number, use left and/or right arrow keys to place the blinking cursor over the digit(s) to

be modified.

c. Use up and down arrow keys to change value.

d. Press ENTER to save change.

10. When done scroll to next parameter to be changed (refer to chart

on Page 2

) by using up and down

arrow keys. Press R to return to the previous screen or S to return to status screen.

11. Repeat process until all parameters shown on chart

on Page 2

are programmed.

12. To end programming press R repeatedly until reaching main menu then press Enter at status. This

will bring you back to monitoring at main screen.