Setting the moisture control and plenum setpoint, Dryer safety circuit, Checking the hour meter – Grain Systems PNEG-1758 User Manual

Page 9: Competitor/dri-tek control panel

Advertising
background image

1. Competitor/Dri-Tek Control Panel

PNEG-1758 Competitor/Dri-Tek Control Panel

9

Setting the Moisture Control and Plenum Setpoint

1. Press the Program (Temperatures) button until the carrot is under the temperature setting to

be changed.

2. Use the UP and DOWN arrow keys to change from the present temperature to the new one. The new

time is automatically entered.

3. Keep pressing the Program (Temperatures) button until the carrot disappears or press the Mode

Select button once to exit.

Dryer Safety Circuit

The Series 2000 Control System continuously checks all safety circuits on the dryer and will automatically
shut the dryer down should a problem occur. The cause of the dryer shutdown will be shown on the LCD
display. To restart the dryer after a safety shutdown, first correct the reason for the shutdown and then
press the Dryer Power Stop button to reset the circuit. Press the Start button.

Figure 1D Series 2000 Control System

Monitoring Grain Temperatures, Plenum Temperature or Timers

Use the mode select to decide which of the modes you want to view.

Checking the Hour Meter

Press the UP arrow key and the total hours on the machine are displayed along with the batch count and
minutes since the last shutdown in five (5) successive screens. The screens appear in the following order:
Hours X 100, balance of hours, balance of minutes, batch count and minutes since last shutdown.
For example, five (5) screens displaying 5 | 23 | 12 | 144 | 188 would be: 523 Hours, 12 minutes on the
Hour Meter, Batch Count at 144 and 188 minutes since the last shutdown.

MOISTURE CONTROL SET POINT
POINT DE CONSIGNE DU CONTRÔLE D’HUMIDITÉ

PLENUM TEMPERATURE SET POINT
POINT DE CONSIGNE DE TEMP DE PLÉNUM

HI LO SPEED
VITESSE HAUTE LENTE
DISCHARGE
DÉCHARGE
LO-FLAME
FLAMME BASSE
HI-FLAME
FLAMME HAUTE
PURGE
PURGE
MOTOR
MOTEUR
OVERLOAD
SURCGARGE

ERROR

ERREUR

NO AIRFIOW
PAS D’ÉCOULEMENT D’AIR
% GRAIN
% GRAIN
°F PLENUM
PLÉNUM F
°C HOUSING
BOITÎER C
VAPOR
VAPEUR
TEMP HI-LIMIT
TEMP LIM-ÉLEVÉE
FLAME OUT
FLAMME ÉTEINTE

PROGRAM

(TIMERS)

PROGRAMME
(MINUTERIES)

PROGRAM

(TEMPERATURES)

PROGRAMME

(TEMPÉRATURES)

PROGRAM

(DELAYS)

PROGRAMME

(DÉLAIS)

MODE SELECT

TIMERS/PLENUM TEMP/

GRAIN TEMP

MODE CHOISI (SELECT)

MINUTERIES/TEMP PLÉNUM/

TEMP GRAIN

HOURS

X 1000

HEURES

X 1000

HOURS

HEURES

DC-2004

LOAD DELAY
DÉLAI DE CHARGE

DRY TIME
TEMPS DE SÉCHAGE

OUT OF GRAIN TIME
TEMPS HORS GRAIN

COOL TIME
TEMPS DE REFROIDISSEMENT

UNLOAD TIME
TEMPS DE DÉCHARGE

UNLOAD DELAY
DÉLAI DE DÉCHARGE