5. 15'-24' Hopper Assembly
34
PNEG-1070 15', 18', 21', 24', 27' and 30' CHT’s
Figure 5B Compression Angle Erection
Using 5/8"-11 x 1-1/2" bolts (S-4109) and 5/8" nuts (S-4110), fasten the compression angle segments to
the support clips on the support columns. A 5/8"-11 x 2-3/4" bolt (S-4108) and 5/8" nut (S-4110) may be
placed in the top hole of the support column for alignment purposes, but will be removed later when the
sidewall base stiffener is to be positioned. Refer to
. Do not tighten bolts until hopper panels are
installed to allow alignment.