6. 27'-30' Hopper Assembly
42
PNEG-1070 15', 18', 21', 24', 27' and 30' CHT’s
Start at the bottom of the hopper and tighten all bolts, including anchor bolts, discharge collar, hopper
panels, splice plates and compression angle segments.
Install rack and pinion roller gate as shown in
, using 5/16" x 3/4" hardware (S-275).
Install “X” bracing as shown in
.
When the hopper structure has been completed, it should be level to within ± 1/8" maximum deviation, as
compared to all other support columns as measured at the top of the compression angle ring. The support
columns must be plumb to within ± 1/2" as measured from top to bottom.
Figure 6H Completed Hopper Assembly
Figure 6I “X” Bracing Rods
Figure 6J