Caulking detail, Chapter 8 caulking detail – Grain Systems Tanks PNEG-972 User Manual

Page 26

Advertising
background image

26

PNEG-972 Construction Manual for 2.66" Corrugation 105' Diameter Tall Tanks (28 Rings and Taller)

8. Caulking Detail

Caulking Detail for Standard (Non-Laminated) Sheets

Figure 8A Standard and Quad Punched Sidewall Sheets as Viewed from Outside

Apply one strip of caulking near the outside edge of the outer sheet and between the outer two (2) rows
of bolts, refer to

Figure 8B

. A strip of caulking 10" long, should be placed along the horizontal seams.

Before bolting the next ring into place, apply one strip of caulking 10" long on the front of the underlapped
sheet at each joint. Also, a 10" strip of caulking is to be placed along the lower horizontal edge of
lapping sheet at every vertical seam. This will fill the space that occurs between the holes caused by the
overlapping sheets. Additional 10" strips must be used to fill larger gaps that occur with heavier gauges
and laminated gauges. See

Page 27

for details on caulking of laminated sheets.

Figure 8B

Advertising