Drying time table – Grain Systems PNEG-1915 User Manual

Page 29

Advertising
background image

1. Drying Time Table

PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision

29

Drying Time Table……..1214 and 2120 (Continued)

Wheat, Barley, Milo...Dry and Cool

Soybeans...Dry and Cool

Canola...Dry and Cool

The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.

140°F

155°F

175°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

15

13

20

32

398

24

28

465

28

23

553

16

13

15

43

300

18

37

350

21

31

417

17

13

12

53

245

14

45

286

17

38

340

18

13

11

62

208

12

53

243

15

45

289

19

13

9

71

181

11

61

211

13

51

251

20

13

8

81

159

9

69

186

11

58

221

21

13

7

91

141

8

78

165

10

66

196

23

13

6

114

113

7

98

132

8

82

157

25

13

5

142

91

5

122

106

6

102

126

120°F

130°F

140°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity Dry

(BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

15

13

23

28

453

26

25

518

30

22

583

16

13

17

38

342

20

33

390

22

29

439

17

13

14

46

278

16

40

318

18

36

358

18

13

12

54

237

14

48

270

15

42

304

19

13

10

63

206

12

55

235

13

49

264

20

13

9

71

181

11

62

207

12

55

233

21

13

8

80

161

9

70

184

10

62

207

23

13

7

100

128

7

88

147

8

78

165

25

13

5

125

103

6

109

118

7

97

133

120°F

140°F

160°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity Dry

(BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

11

9

18

36

362

24

28

465

29

23

569

12

9

14

47

273

18

37

351

22

30

429

13

9

11

58

222

15

45

286

18

37

349

14

9

10

68

189

12

53

243

15

43

297

15

9

8

78

164

11

61

211

13

50

258

16

9

7

89

145

9

69

186

12

57

227

17

9

7

100

128

8

78

165

10

64

202

18

9

6

112

115

7

87

147

9

72

180

19

9

5

126

102

7

98

132

8

80

161

Drying table based on 100% unload rate of…...1970 BPH

Advertising