Drying time table – Grain Systems PNEG-1915 User Manual

Page 84

Advertising
background image

1. Drying Time Table

84

PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision

Drying Time Table……..3620 and 1500 (Continued)

Corn...Full Heat

Wheat, Barley, Milo...Dry and Cool (#1 and #2 Cooling)

Soybeans...Dry and Cool (#1 and #2 Cooling)

The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.

170°F

190°F

210°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out*

21

17

100

30

2772

22

17

91

35

2510

100

30

2772

23

17

79

40

2189

92

34

2554

100

30

2772

24

17

70

45

1934

81

39

2256

93

34

2579

25

17

62

51

1720

72

44

2007

83

38

2293

26

17

55

57

1534

65

49

1790

74

43

2046

27

17

49

64

1371

58

55

1600

66

48

1828

28

17

44

72

1227

52

61

1431

59

54

1636

29

17

40

80

1100

46

69

1283

53

60

1466

30

17

36

89

988

42

76

1153

48

67

1317

32

17

29

109

806

34

93

940

39

82

1075

35

17

22

142

618

26

122

721

30

107

823

*Represents the target moisture out of the dryer. Expected final moisture in the bin is

…...

15.0%

140°F

155°F

175°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

15

13

65

33

1793

75

28

2092

90

24

2490

16

13

49

43

1351

57

37

1577

68

31

1877

17

13

40

53

1102

46

46

1285

55

38

1530

18

13

34

63

936

39

54

1092

47

45

1300

19

13

29

72

814

34

62

949

41

52

1130

20

13

26

82

717

30

70

836

36

59

996

21

13

23

92

636

27

79

743

32

66

884

23

13

18

115

508

21

99

592

25

83

705

25

13

15

143

409

17

123

477

20

103

568

120°F

130°F

140°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

15

13

73

29

2032

84

25

2323

94

22

2613

16

13

55

38

1532

63

33

1751

71

30

1970

17

13

45

47

1249

51

41

1427

58

36

1606

18

13

38

55

1061

44

48

1212

49

43

1364

19

13

33

64

922

38

56

1054

43

49

1186

20

13

29

72

813

34

63

929

38

56

1045

21

13

26

81

721

30

71

825

33

63

928

23

13

21

102

576

24

89

658

27

79

740

25

13

17

126

464

19

111

530

21

98

596

Drying table based on 100% unload rate of…...2772 BPH

Advertising