Drying time table – Grain Systems PNEG-1915 User Manual

Page 67

Advertising
background image

1. Drying Time Table

PNEG-1915 VN2 Portable Dryer Drying Charts for All Models of Vision

67

Drying Time Table……..2420 and 1000 (Continued)

Wheat, Barley, Milo...Dry and Cool (#1 and #2 Cooling)

Soybeans...Dry and Cool (#1 and #2 Cooling)

Canola...Dry and Cool

The above drying capacities are estimates based on drying principles, field results and computer
simulations. Variances may occur due to grain physiological factors (kernel size, chemical composition,
variety, maturity), excessive fines, weather conditions, etc.

140°F

155°F

175°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

15

13

32

33

886

37

28

1033

44

24

1230

16

13

24

43

668

28

37

779

33

31

927

17

13

20

53

544

23

46

635

27

38

756

18

13

17

63

462

19

54

539

23

45

642

19

13

15

72

402

17

62

469

20

52

558

20

13

13

82

354

15

70

413

18

59

492

21

13

11

92

314

13

79

367

16

66

437

23

13

9

115

251

11

99

293

13

83

348

25

13

7

143

202

9

123

236

10

103

281

120°F

130°F

140°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

15

13

36

29

1004

41

25

1147

47

22

1291

16

13

27

38

757

31

33

865

35

30

973

17

13

22

47

617

25

41

705

29

36

793

18

13

19

55

524

22

48

599

24

43

674

19

13

16

64

456

19

56

521

21

49

586

20

13

14

72

401

17

63

459

19

56

516

21

13

13

81

356

15

71

407

17

63

458

23

13

10

102

284

12

89

325

13

79

366

25

13

8

126

229

9

111

262

11

98

294

Drying table based on 100% unload rate of…...2772 BPH

120°F

140°F

160°F

Moisture

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% Unload

Rate

Dry Time

(Min.)

Capacity

Dry (BPH)

% In

% Out

11

9

29

36

802

37

28

1031

45

23

1260

12

9

22

48

604

28

37

777

34

30

950

13

9

18

59

493

23

46

633

28

37

774

14

9

15

69

419

19

54

538

24

44

658

15

9

13

80

364

17

62

468

21

51

572

16

9

12

90

321

15

70

412

18

57

504

17

9

10

102

285

13

79

366

16

65

447

18

9

9

114

254

12

89

326

14

73

399

19

9

8

128

227

11

99

292

13

81

357

Drying table based on 100% unload rate of…...2772 BPH

Advertising