Fan pad location, Fan specifications – Grain Systems PNEG-163-08 User Manual

Page 24

Advertising
background image

4. Fan Specifications

24

PNEG-163-08 Centrifugal Fan

Fan Pad Location

Fan pad should be perpendicular to bin wall. Fan discharge centerline should lie on bin centerline.
Recommended thickness for pad is 4" minimum. Top surface of pad should be 2" below bin
foundation. Fans with downwind heaters require fan pad to be 48" wide and add 33" onto length (D).

IMPORTANT: Fan pad and fan must be level and smooth for proper operation. Vibration problems can

result from improper fan leveling.

Figure 4F

Front of pad should be perpendicular to bin wall. Recommended thickness for fan pad is
4" minimum. Surface of pad should be 2" below the bin foundation. Pad for heater not required.

TR-4734
A = 20" without heater
A = 44" with heater
B = 10"
C = 40"
D = 40"

TR-7048
A = 45" without heater
A = 69" with heater
B = 10"
C = 40"
D = 48"

TR-6918 and
TR-6919
A = 32" without heater
A = 65" with heater
B = 13"
C = 48"
D = 52"

TR-7049
A = 45" without heater
A = 78" with heater
B = 13"
C = 48"
D = 52"

TR-6207
A = 42" without heater
A = 78" with heater
B = 13"
C = 48"
D = 60"

TR-6958
A = 55" without heater
A = 85" with heater
B = 13"
C = 48"
D = 60"

TR-6853 (Double inlet)
A = 54" without heater
A = 88" with heater
B = 28"
C = 100"
D = 60"

TR-4013
A = 36" without heater
B = 13"
C = 48"
D = 60"

TR-6944
A = 48" without heater
B = 13"
C = 48"
D = 60"

Advertising