Lubrication and bearings, Lubrication procedure, With grease outlet plug – Grain Systems PNEG-163-08 User Manual

Page 30: Without grease outlet plug

Advertising
background image

6. User Servicing Instructions and Troubleshooting

30

PNEG-163-08 Centrifugal Fan

Lubrication and Bearings

Bearing grease will lose its lubricating ability over time, not suddenly. The lubricating ability of a grease
(over time) depends primarily on the type of grease, the size of the bearing, the speed at which the bearing
operates and the severity of the operating conditions. Good results can be obtained if the following
recommendations are used in the maintenance program. Type of grease: A high grade ball
or roller bearing grease should be used.

Recommended grease for standard service conditions:

Polyrex EM (Exxon Mobile)

Equivalent and compatible greases include:

Texaco Polystar

Rykon Premium #2

Pennzoil Pen 2 Lube

Chevron SRI.

Lubrication Procedure

Be sure that the grease you are adding to the motor is compatible with the grease already in the motor.

With Grease Outlet Plug

1. Clean all grease fittings.

2. Remove grease outlet plug.

3. Add the recommended amount of grease.

4. Reinstall grease outlet plug.

Without Grease Outlet Plug

This requires disassembly of the motor. Contact local motor shop for assistance.

Volume of Grease to Relubricate Bearings (Teaspoons)

NEMA Frame Size

Qty

Up to 210 incl.

2

Over 210 to 280 incl.

3.9

Over 280 to 360 incl.

5.2

Over 360 to 449 incl.

13.4

DANGER

To avoid damage to motor bearings, grease must be free of dirt.

Advertising