Operation – Grain Systems PNEG-1711 User Manual

Page 13

Advertising
background image







PNEG - 1711

Page 13 of 22

06/30/2009

Digital Thermostat Owner’s Manual

6. Once the control has been wired, refer to Figure 4 for mounting the new controller to the control panel door.

The S-7931 nuts are already installed in the bottom assembly (Figure 3). There are recessions on the bottom
of the corners of the box that fit the nuts. Make sure to place the gasket between the two box pieces.

Figure 4 - Assembly Drawing


7. The GSI Digital Thermostat is now ready for operation. Refer to Section 3 for operation instructions.

3. Operation

3.1 Setting Temperature Setpoint

Press and release the “SET” button to enter the temperature setpoint menu. Here the user may press and release the “UP”
or “DOWN” button to adjust the setpoint accordingly, incrementing/decrementing by one. The setpoint can be adjusted
rapidly by holding the “UP” or “DOWN” button. To accept the setpoint, press and release the “SET” button. The controller is
still running in the background while in this menu and the new setpoint is not accepted until the “SET” button is pressed.
While in the setpoint menu, if the user allows approximately twenty-five seconds to pass without pressing a button, the menu
is exited and the new setpoint is not saved.

Advertising