Operating procedure, Deluxe centrifugal heater – Grain Systems PNEG-588 User Manual

Page 16

Advertising
background image

16

Deluxe Centrifugal Heater

OPERATING PROCEDURE

Btu's Per Gauge Pressure (Psi) Natural Gas Models (Approximate)

High Temperature

14

4195000

12

3886000

10

3555000

8

3180000

6

2749000

4

2375000

2

1590000

Operating Pressure (PSI)

Low Temperature

7

500000

6

478000

5

436000

4

390000

3

338000

2

276000

1

195000

Operating Pressure (PSI)

60

1

1

.75

1

1

1

1.75

1.25

1

2

2

1.75

2.5

2

2

3

2.75

2.5

Fan Model

10HP

15HP

20HP

25HP

30HP

40HP

Heat Rise Degrees F

Static

Pressure

2"

4"

6"

2"

4"

6"

2"

4"

6"

2"

4"

6"

2"

4"

6"

2"

4"

6"

80

1.5

1.5

1.25

1.75

1.5

1.25

2.5

2

1.75

3.25

3

2.5

4

3.5

3

6

5

4

100

2

1.75

1.5

2.5

2

1.5

3.5

3

2.5

5

4

3.5

6.5

5

4

10

8

6.5

120

2.5

2

1.75

3.25

2.5

1.75

5

4

3.25

7.5

6

5

9

8

6

14

11

9

140

3

2.5

2

4

3.25

2.25

7

5

4

10

8.5

7

13

11

8.5

15

13

160

3.5

3

2.25

5

4

3

9.5

7

5

13

11

9.5

14

11

180

4

3.5

2.5

7

5.5

3.75

12

9

7

14

12

14

Gauge Pressure (Psi) Required To Maintain Temperature (Approximate)

(High Temp Units Only)

All

Models

All

Models

Advertising