4. Electrical Power Supply

PNEG-634 2000 Top Dry Fan/Heater

29

Electrical Load Information

The

Chart below

provide information for the electrician wiring the grain dryer and are a reference guide for

parts. It is recommended that you contact the local power company and have a representative survey the
installation to see that the wiring is compatible with their system and that adequate power is supplied to
the unit. NOTE: The only thing connected to the recommended service amps should be the grain dryer.
Standard electrical safety procedures should be used. (Refer to the National Electrical Code Standard
Handbook by the National Fire Protection Association.) A qualified electrician should make all electrical
wiring installations.

Dryer Fan Size

Voltage

Horsepower

Full Load Amps

Fuse (Slow Blow)

Breaker

28"

220V 1 PH

10-12

48

100

100

208V 3 PH

10-12

35

80

80

220V 3 PH

10-12

33

80

80

380V 50 Hz

10-12

15

40

40

460V 3 PH

10-12

17

40

40

575V 3 PH

10-12

15

40

40

36"

220V 1 PH

10-16

78

150

150

208V 3 PH

15

44

125

125

220V 3 PH

15

39

100

100

380V 50 Hz

15

27

80

80

460V 3 PH

15

20

50

50

575V 3 PH

15

16

40

40

40"

220V 1 PH

10-16

78

150

150

208V 3 PH

15

44

125

125

220V 3 PH

15

39

100

100

380V 50 Hz

15

27

80

80

460V 3 PH

15

20

50

50

575V 3 PH

15

16

40

40

42"

208V 3 PH

30

80

150

150

220V 3 PH

30

74

150

150

380V 50 Hz

30

39

100

100

460V 3 PH

30

37

100

100

575V 3 PH

30

30

80

80

42"

208V 3 PH

40

108

200

200

220V 3 PH

40

102

200

200

380V 50 Hz

40

47

100

100

460V 3 PH

40

51

100

100

575V 3 PH

40

40

100

100