Rotary switch and horn wiring – Grain Systems PNEG-634 User Manual

Page 35

Advertising
background image

4. Electrical Power Supply

PNEG-634 2000 Top Dry Fan/Heater

35

Rotary Switch and Horn Wiring

A drying chamber overflow rotary switch and a storage chamber high level rotary switch can be used
to let the operator know when the drying chamber or the storage chamber is full.

Figure 4I

details one

possible way of wiring both the drying chamber and the storage chamber rotary switches so that the horn
will sound when either the drying chamber or the storage chamber is full. To wire the rotary switches and
the horn do the following:

1. Run two (2) wires between an ON/OFF switch and the storage chamber rotary switch.

2. Run three (3) wires between the storage chamber rotary switch and the drying chamber

rotary switch.

3. Run two (2) wires between the drying chamber switch and the horn.

4. Connect the wires as shown in

Figure 4I

.

Figure 4I Wiring for the Rotary Switches and Horn