Series 2000 Autoflow Operation

Pre-Season Checks

Before the dryer is filled, thoroughly inspect

the unit and check the operation of the dryer as fol-
lows. When entering the bin take great caution. Never
enter a bin where grain is present.

Set Control Switches

MOISTURE CONTROL Switch - “On”
AERATION FAN Switch - “Off”
LOAD AUGER Switch - “Off”
FAN Switch - “Off”
HEATER Switch - “Off”
DUMP Switch - “Auto”
DRY and HOLD Switch - “Off”
All Emergengy Stop Switches must be pulled

out. These are located on Fan Heater, Main Control
Panel, Fill System Box, and Actuator Box.

Fill 1 Motor Overload

The thermal overload in the fill system control

box for fill system number one has tripped, indicating
an overcurrent condition. The overload must be reset
manually.

Fill 2 Motor Overload

The thermal overload in the fill system control

box for fill system number two has tripped, indicating
an overcurrent condition. The overload must be reset
manually.

Aeration Overload

The thermal overload in the fill system control

box for the aeration fan has tripped, indicating an

overcurrent condition. The overload must be reset

manually.

Grain High Limit

The grain temperature in the drying chamber is

too high. The grain temperature reached a point where
it was five degrees less than the plenum cycle setpoint.

ERROR MESSAGES/
PRE-SEASON CHECKS

Wet Supply Empty Press <Enter> To Dry Re-

maining Grain

This message is displayed when the start

button is pushed and grain has fallen away from the
wet supply rotary switch and there is still grain against
the drying chamber low level rotary switch. If the
enter button is pushed the dryer will restart, but the fill
system(s) will not restart.

Cannot Start Dryer Wet Supply Empty

This message is displayed when the start

button is pushed and grain has fallen away from the
wet supply rotary switch and there is no grain against
the drying chamber low level rotary switch. Grain will
have to be put into the wet supply tank or the drying
chamber to start the dryer.

Low Level Switch Exposed

This message is displayed when grain falls

away from the drying chamber low level rotary switch
after the Low Level Switch Delay has reached zero. If
the error is being caused due to the settling of grain
after the fans start the time on the Low Level Switch
Delay can be lengthened.

Control Power Switch

Turn the control power switch on. The switch

will light up. If a fault is found an error message will be
displayed on the screen. If all are found safe, the main
drying screen will be displayed.

Drying Chamber

Enter the drying chamber and inspect each

dump hopper for obstructions that may inhibit the flow
of grain into the dump chutes. Make sure that the gap
between the discharge flow plates and the floor sheets
is a minimum of 1-1/2”. All discharge flow plates
should be adjusted evenly around the bin. Inspect each
discharge flow plate and make sure that the bottom
brackets on each flow plate have not collapsed due to
pressure from walking around the drying chamber.
Inspect the leveling bands. Make sure that all leveling
bands are installed properly and in are good shape.