Installation and operating, Chapter 6 installation and operating, Bin configuration plenum temperatures – Grain Systems PNEG-297 User Manual

Page 14: Bin configuration, Plenum temperatures

Advertising
background image

14

PNEG-297 Chi-Town Heater

6. Installation and Operating

Bin Configuration

Figure 6A

IMPORTANT: When mounting two (2) heaters on a bin it is imperative that they be situated as in

Figure 6A

. Plenum thermostat must be to the right of primary heater and primary heater

must be to the right of secondary heater.

Plenum Temperatures

IMPORTANT: Do not exceed plenum temperatures listed in table

below

.

Operating Temperature Table

NOTE: This table is not intended as a drying guide. It should be used as a reference for setting maximum

plenum temperature for safe operation.

Low Temperature

Batch

High Temperature Batch

Dry No Stirring

High Temperature

with Stirring

Continuous Flow

(Recirculating)

Corn

5°-20° above

Ambient Temperature

120°

140°

160°

Rice

5°-10° above

Ambient Temperature

100°

100°

Not Recommended

Beans and

Wheat

5°-20° above

Ambient Temperature

110°

120°

Not Recommended

Advertising