Operating instructions, Chapter 7 operating instructions, Heater operation – Grain Systems PNEG-297 User Manual

Page 15

Advertising
background image

PNEG-297 Chi-Town Heater

15

7. Operating Instructions

Heater Operation

1. Thermostat must be wired into heater control box for heater to operate.

2. Open all manual shut off valves to heater unit.

3. Start fan. This will supply power to heater.

4. Turn thermostat dial to its highest setting.

5. Turn heater toggle switch to ON.

6. Heater should now be lit. If not, check to see that all gas is on and thermostat is wired in.

7. Watch thermometer on plenum and when it reaches desired temperature turn thermostat back slowly

until heater cycles OFF.

8. Gas pressure should be adjusted so burner is on 75% of the time. (See charts on

Page 14

.)

9. Watch plenum temperature as burner goes through a few cycles to be sure it is operating properly.

Figure 7A Propane Vapor Pipe Train