3. Bin Assembly
32
PNEG-2400 CFL Commercial Farm 4" Corrugation Externally Stiffened Grain Bin
Figure 3Q Alignment Punches and Clamp
3. Install five (5) bolts along the top and bottom of the door frames connecting the inner and outer door
frames together using bolts (S-9445) and nuts (S-9373).
NOTE: Caulk along bolt connections between door frames.
4. To install side bolts for initial installation:
•
For triple row punched door frames, locate bolts around door frame perimeter.
•
For double row punched door frames, fill top, bottom and three (3) middle bolt hole locations.
NOTE: Install bolts (S-9445) and nuts (S-9373) to secure door frames to sidewall sheets only in
suggested locations, leaving holes open for the hinge housing brackets.
5. Locate and install the inner door hinge housing brackets (NCWT0386 for triple punched frame or
NCWT0406 for double punched frame) to the inner door frame as shown
.
Tighten bracket bolts only finger tight to allow for future adjustment.