Grain Systems Tanks PNEG-2400 User Manual
Page 53

3. Bin Assembly
PNEG-2400 CFL Commercial Farm 4" Corrugation Externally Stiffened Grain Bin
53
Refer to 4" commercial tank bolting requirements for complete bolt usage on
and
.
NOTE: Bolts with sealing washers are pre-assembled.
0.375" x 1.000" Hex flanged head without a plastic sealing washer.
This bolt is used to splice the stiffeners together on the flanges of 8 gauge and thinner stiffeners.
A flange nut is used on the nut side of the connection. They are also used on the roof rafter splices
for some commercial roof systems.
0.375" x 1.500" Hex flanged head without a plastic sealing washer.
This bolt is used to attach the flanges of the 5 gauge and 6 gauge stiffeners to the splice plates
and splice laminated stiffeners together. A flange nut is used on the nut side of the connection.