Series 2 Chain Conveyors

Slack Chain Assembly

The GSI Group offers a slack chain detector
system as an option for its 26” and 32” tall Series
II enmasse conveyors. Depending on working
conditions and/or environment, either a NEMA 4
or a NEMA 9 limit switch is available.

Begin installation of optional slack arm assembly by
first cutting a 12” x 5” rectangular hole in the head
section cover; see illustration below.

Next, center the slack chain assembly over the
rectangular opening. Mark the locations for the
four (4) 7/16” diameter holes. Temporarily re-
move the slack chain assembly, and drill the four
7/16” diameter holes.

Before attaching slack chain assembly to the
conveyor, apply sealant to bottom surfaces of
slack chain assembly.

Fasten slack chain assembly to conveyor with 3/8”
hardware. See illustration below regarding direc-
tion of slack chain assembly on the conveyor.

After installation, check that the clearance be-
tween the UHMW paddle in the slack chain
assembly and the UHMW flights on the chain is
approximately 1/2” to 3/4”. Adjust if necessary.

Options

Top Mount Slack Chain

with NEMA 4 limit switch

Top Mount Slack Chain

with NEMA 9 limit switch