14. Roof Assembly Instructions

92

PNEG-4042 40 Series 42' and 48' Diameter Bins

42' and 48' Flat Top Instructions

Figure 14D

Ref #

Part #

Description

Ref #

Description

A

“A” Diameter: Small = 61-1/4" (155.6 cm)

F

Platform Flashing

B

CRP-4964

Hold-Down Strap

G

5/16" Washer (Both ends)

C

CRP-4966

Small Roof Peak Platform Weldment

H

5/16" x 1-1/4" Bin Bolt (Both ends of strap.)

D

S-7229

1/4" x 1" Sealing/Self-Drilling Tek Screw

I

Apply a bead of rope caulking under flashing.

E

CRP-4968

Platform Bulb Seal Strip

* NOTE: On 42' (12.80 m) and 48' (14.63 m) roofs,
the roof nose bolt cannot be shared with the platform
hold-down strap. Locate six (6) equally spaced bolts
in the bottom row of the 6' (1.83 m) “Z” collar to
accept this strap on these roofs. Double nut the
six (6) bolt locations as shown in

Figure 14D

.