15. Roof Truss Details

96

PNEG-4042 40 Series 42' and 48' Diameter Bins

42' and 48' Rafter/Splice/Support Intersection Detail

Figure 15D

NOTE: Field drill eight (8) holes in the web and four (4) holes in the flange evenly distributed over the

length of the part in addition to any splice bolts that are used.

Ref #

Part #

Description

A

PR-1874

Rafter Splice Angle

B

CRP-5185

Roof Rafter Support Angle

C

Rafter Section