Toolbox 5.1 algorithm – trim page, Toolbox 5.1 algorithm – calibration page, Calibration page – TC Electronic Broadcast 6000 User Manual

Page 70: Generator, Output level

Advertising
background image

Toolbox 5.1

66

System 6000 MKII Algorithms

Ref Level 1, 2 and 3
Range -100 to 0 dB
For convenient switching between 3  different
Reference Levels. To adjust level press the value
field when Ref. Level is activated and use Fader
6. To select Reference Level 1 to 3 press the oval
keys next to the value fields.

Toolbox 5.1 algorithm – trim page

Toolbox 5.1 algorithm – trim page

Input Levels
Range: -100 to 0 dB
Controls the Input level for each of the 6 chan-
nels.

Output Levels
Range: -100 to 0 dB
Controls the Output level for each of the 6 chan-
nels.

Toolbox 5.1 algorithm

– calibration page

Toolbox 5.1 algorithm – calibration page

Calibration page

Test signal generator (Oscillator)
Toolbox 5.1 integrates a comprehensive test-
signal generator meant for aligning the monitor
system.

When a Test signal is selected, the Input source
will not be present on the Outputs.

The Calibration tone is delivered on the very In-
put of the Toolbox.

Generator

Type
Range: Sine, PinkNoise, WhiteNoise
LPF Pink Noise
(Low Pass Filtered Pink noise),
HPF Pink Noise
(Hi Pass filtered pink noise)
This parameter selects the Signal generator
type.

Default: Sine

Sine Frequency
Range: 20 Hz to 20 kHz
Selects the frequency when Osc. Type is set to
Sine.

Default: 1 kHz

Output Level

Output Level (RMS)
Range: -60 to 0 dBFS
60 to -6 dB in 1 dB steps
-6 to 0 dB in 0.1 dB steps
Sets the level of the selected generator to all six
Output channels.

Default: -20 dBFS

LFE Trim
Range: -12 to 0 dB, in 0.1 dB steps
Attenuates the LFE Output channel relative to the
main test-generator level.

Please note that thru channels are “hardwired”
without any adjustment options.

Advertising