Table 9. adc configuration registers (continued) – Rainbow Electronics MAX16066 User Manual
Page 20
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16065/MAX16066
20 _____________________________________________________________________________________
Table
9. ADC Configuration Registers (continued)
REGISTER ADDRESS
FLASH
ADDRESS
BIT RANGE
DESCRIPTION
44h
244h
[1:0]
ADC5 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
[3:2]
ADC6 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
[5:4]
ADC7 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
[7:6]
ADC8 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
45h
245h
[1:0]
ADC9 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
[3:2]
ADC10 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
[5:4]
ADC11 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted
[7:6]
ADC12 Full-Scale Range:
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = Channel not converted