Register Map (continued)

FLASH

ADDRESS

REGISTER

ADDRESS

READ/

WRITE

DESCRIPTION

278

078

R/W

Sequence delay for Slot 2 and Slot 3

279

079

R/W

Sequence delay for Slot 4 and Slot 5

27A

07A

R/W

Sequence delay for Slot 6 and Slot 7

27B

07B

R/W

Sequence delay for Slot 8 and Slot 9

27C

07C

R/W

Sequence delay for Slot 10 and Slot 11

27D

07D

R/W

Primary sequence final slot, sequence delay for Slot 12

MISCELLANEOUS

27E

07E

R/W

MON1/MON2 slot assignment

27F

07F

R/W

MON3/MON4 slot assignment

280

080

R/W

MON5/MON6 slot assignment

281

081

R/W

MON7/MON8 slot assignment

282

082

R/W

MON9/MON10 slot assignment

283

083

R/W

MON11/MON12 slot assignment

284

084

R/W

EN_OUT1/EN_OUT2 slot assignment

285

085

R/W

EN_OUT3/EN_OUT4 slot assignment

286

086

R/W

EN_OUT5/EN_OUT6 slot assignment

287

087

R/W

EN_OUT7/EN_OUT8 slot assignment

288

088

R/W

EN_OUT9/EN_OUT10 slot assignment

289

089

R/W

EN_OUT11/EN_OUT12 slot assignment

28A

08A

R/W

Customer use (version)

28B

08B

R/W

PEC enable/SMBus address

28C

08C

R/W

Lock bits

28D

08D

R

Revision code

NONVOLATILE FAULT LOG

200

R/W

Sequence state

201

R/W

Fault flags, MON1–MON8

202

R/W

Fault flags, MON9–MON12, OC, EXTFAULT

203

R/W

MON1 ADC output

204

R/W

MON2 ADC output

205

R/W

MON3 ADC output

206

R/W

MON4 ADC output

207

R/W

MON5 ADC output

208

R/W

MON6 ADC output

209

R/W

MON7 ADC output

20A

R/W

MON8 ADC output

20B

R/W

MON9 ADC output

20C

R/W

MON10 ADC output

20D

R/W

MON11ADC output

20E

R/W

MON12 ADC output

20F

R/W

Current-sense ADC output