Figure 8-4 – Rainbow Electronics ATtiny43U User Manual

Page 39

Advertising
background image

39

8048B–AVR–03/09

Figure 8-4.

Input and Output Voltages of Boost Converter.

When input voltage V

BAT

falls below V

STOP

the converter enters Stop Mode and output voltage

V

CC

begins to fall. When converter output voltage, i.e. the supply voltage of the microcontroller,

falls below V

POT

the MCU will go into reset.

Figure 8-5

illustrates how the boost converter output changes with load current. As converter

output voltage rises above the power-on threshold the microcontroller is brought on-line and cur-
rent consumption steps up to a level sufficiently high for the converter to remain in Active
Regulated Mode of operation.

Figure 8-5.

Output Voltage vs. Load Current of Boost Converter.

Note:

The figure is not to scale. Typically, the switching time (rising voltage) is measured in hundreds of
microseconds and idle time (falling voltage) is measured in seconds.

V

CC

t

V

POT

V

START

V

BOOST

V

STOP

V

BAT

STOP

STOP

ACTIVE

RESET

ACTIVE

RESET

CONVERTER:

MCU CORE:

V

CC

t

I

LOAD

V/A

V

CCMIN

V

CCMAX

LOW CURRENT MODE

ACTIVE, REGULATED

MODE:

V

CCNOM

I

MS

REGULATED