MG260 Product Specification

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without prior written
agreement.



POWER SUPPLY


ONKEY

T

on/off-hold

(1 s min)



INTERNAL RST




STATE OF THE MODULE



Module OFF

I

BB+RF

< 10 µA

T

rst

(240 ms typ)

RESET mode

I

BB+RF

=20 to 40 mA



Module ON

I

BB+RF

<120 mA

(no loc. update)


AT answers « OK »

Module READY

SIM and Network dependent

I

BB+RF

= overall current consumption (Base Band + RF part)



Figure 9: Power-ON sequence diagram (no PIN code activated)

2.5.2.2.2 Power OFF

To properly power OFF the module, the application must set the ONKEY signal to low and
then send the AT+CPOF command to de-register from the network and switch off the
module. Once the « OK » response is issued by the module, the power supply can be
switched off.

POWER SUPPLY

ONKEY

AT COMMAND

AT+CPOF

OK response



STATE OF THE MODULE

Module

READY

Network dependent

Module OFF

I

BB+RF

<100 µA

I

BB+RF

= overall current consumption (Base Band + RF part)

Figure 10: Power-OFF sequence diagram