Peterson Strobe Center 5000-II User Manual

Page 11

Advertising
background image

Page 9

Key #1 returns to the Setup menu.
Key #2 saves new values and returns to the Setup menu.
Key #3 returns to Run Mode and uses new values.
(new value are not put into startup memory with #3)

5. CUSTOMIZING THE START-UP MEMORY SETTINGS

If you desire the Strobe Center 5000 to always start-up in a different pitch standard than A=440, to a key other than "C"
(band directors may desire B=, for example), or with different settings of the Image Clarifier and +2/-1 DISPLAY controls,
it is easy to do.

a. In the Run Mode menu, make the adjustment to the key you desire by pressing the KEY button as just described.

Choose the display mode you desire of NORMAL, +2, or -1 by pressing the DISPLAY +2 / -1 button as described
previously.

b. Press the #1 function key to call up the Setup menu. Then press the #1 function key three more times (sequencing

through the #1 function key labels of OPTN {OPTION}, NEXT, and NEXT) to go through the screens of
RECALIBRATE TUNER?, and SET IMAGE CLARIFIER. As you proceed through each of these menus, check
that the settings are those you desire for the start-up memory values. You may adjust these values as needed until
you reach the menu screen:

STORE VALUES IN
MEMORY?

NO YES RUN

1

2

3

4

c. You are now asked if you want to permanently store the choices you have just made into the "STANDARDS" or

power-up memory of the tuner. The power-up memory includes the user selection of the pitch frequency chosen
for middle A (A4), LOW or HIGH register for the Image Clarifier, the Display Mode (+2, -1, or NORMAL), and
the KEY in which your instrument is tuned (C, B=, F, or E=). The #2 key button (YES) will rewrite the power-up
memory of the tuner and return you to the Setup menu; key #1 (NO) will simply return you to the Setup menu
allowing you to re-sequence through the steps of the Setup menu to verify and/or reset your selections before
proceeding with the tuning process. Pressing the #3 key (RUN) will enter the new values you have selected and
return you directly to the Run mode; however, these new values will not be entered into the power-up memory.

KEY = xx
A = xxx 00 ¢

xxx xx

SETUP IMAG

1

2

3

4

d. At the Setup menu press key #3 labeled RUN to return to the normal running mode of the tuner. You are now ready

to begin tuning with the new parameters you have set.