2.6 Three Phase Power Connections

Figure 2. Three Phase Control Box Power Connections


1. Remove control box cover.
2. Insert power supply cable through cable gland or assemble to (optional) plug.
3. Connect power leads L1, L2, and L3 to relay K21.
4. Connect ground wire PE (GRD) to terminal strip (2). Refer to wiring diagram.
5. Tighten terminal screws.
6. Tighten cable gland or (optional) connector to secure power cable.
7. Replace control box cover.
8. Attach pushbutton assembly to plug connection X23.