2.7

Single Phase Power Connections

Figure 3. Single Phase Control Box Power Connections





1. Remove control box cover.
2. Insert power supply cable through power cable gland (Figure 3
).
3. Connect power leads L1 and L2 to terminal strip (Figure 3
).
4. Connect ground wire PE to terminal strip (Figure 3
). Refer to wiring diagram.
5. Insure terminals are tight
6. Tighten cable gland or connector (Figure 3
) to secure power cable.
7. Replace control box cover.
8. Attach pushbutton assembly to plug (Figure 3
).








PE

L1

L2

POWER

CABLE

GLAND

PUSHBUTTON

PLUG