6 i/o extension board (slot d), 7 system bus board (slot e, option), 15 control voltage transformer – R&M Materials Handling VARIABLE SPEED CONTROLS ControlMaster Plus Service Manual User Manual

Page 19

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

19/83

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

28

ROC1

Relay output, 250V 8A, normal open

29

ROC1

Relay contact ROC1 closes when inverter is powered and no faults occurs

Relay contact ROC1 opens if the SSU has tripped in:

Overspeed

Speed difference

Zero speed

Relay test fault

Watch dog fault

LED

Blinking

Status

Red

1Hz

OK

Yellow

0.25Hz

OK

Yellow

4Hz

Board internal fault or communication fault with control unit

1.14.6 I/O Extension board (Slot D)

NXOPTB9 / I/O Extension board

ID: 52305691

YELLOW

1

2

3

4

5

6

7

8

Terminal

Signal name

Description

1

DID1

Not used

2

DID2

42-240Vac 50/60Hz

3

DID3

42-240Vac 50/60Hz

4

DID4

42-240Vac 50/60Hz

5

DID5

42-240Vac 50/60Hz

6

COM

Common for DID1-DID5

7

ROD1

Relay output, 250V 8A, normal open

For fan of braking resistor unit

8

ROD1

The threshold voltage for digital inputs DID1-DID5 is 35VAC.

LED

Blinking

Status

Yellow

0.25Hz

OK

Yellow

4Hz

Board internal fault or communication fault with control
unit

1.14.7 System bus board (Slot E, option)

NXOPTD1L System bus board

ID: 52354858

H1 H2 H3 H4

Terminal

Signal name

Description

H1

RX1

SystemBus optical input 1.

H2

RX2

SystemBus optical input 2.

H3

RX3

SystemBus optical output 1.

H4

RX4

SystemBus optical output 2.

Optical cables

Specification

ID:

Length
[m]

Bend radius

SYS-1M

52354911

1

> 35mm ( >1.3 inch)

SYS-2M

52354876

2

> 35mm ( >1.3 inch)

SYS-4M

52354912

4

> 35mm ( >1.3 inch)

1.15 Control voltage transformer

Power of control voltage transformer has to be n * 50VA + 50VA (min. 250VA), n = number of inverters. This power does
not have to be added to otherwise needed transformer power.

Advertising