2.2 Storing and restoring parameters

2.2.1 User parameters

-

File “User parameters” is stored in inverter’s control unit.

-

User parameters are recommended to save after final set up.

-

The whole parameterset can be stored to User parameters with parameter B 4.1.2.

-

“Save User Par / Enter <-“, press “Enter”

-

Parameters can be restored from User parameters with parameter B 4.1.3.

-

“Load User Par / Enter <-“, press “Enter”

-

After restoring always check the motor parameters.

Parameters in use can be compared to User parameters by parameter S 6.6.2.

m

Parameters restored from User parameters are reseted after power off, unless they
are not confirmed with “Enter” one by one. Easiest way to restore User parameters
permanently is to compare parameters to User parameters by parameter S 6.6.2 and
adjust them to the same value.

2.2.2 Default parameters

-

File “Default parameters” is stored in inverter’s control unit.

-

Default parameters are saved at the factory and they should not be changed. In default parameters there are the
same parameter values as shown in parameter list delivered with inverter. Since serial number 03L50700

-

Parameters can be restored from Default parameters with parameter B 4.1.1.

-

“Load Default Par / Enter <-”, press “Enter”

-

After restoring always check the motor parameters.

-

Parameters in use can be compared to Default parameters by parameter S 6.6.1.

-

Value “0” at parameter S 6.6.1. means that parameters in use are identical to Default parameters

m

Parameters restored from Default parameters are reseted after power off, unless
they are not confirmed with “Enter” one by one. Easiest way to restore Default
parameters permanently is to compare parameters to Default parameters by
parameter S 6.6.1 and adjust them to the same value.

2.2.3 Keypad settings

-

File “Keypad settings” is stored in keypad

-

Default value for parameter P 6.5.4 is “On”. This makes every change to be stored to file “Keypad settings”.

-

The whole parameterset can be stored to file “Keypad setting” with parameter S 6.5.1.

-

“Up to keypad / Select ->”, press “->”

-

“All param.” blinks on display, confirm with enter.

-

Parameters can be restored from keypad’s file “Keypad settings” with parameter S 6.5.2.

-

“Down from keypad / Select ->”, press “->”

-

“All param.” blinks on display, confirm with enter.

-

After restoring always check the motor parameters.

2.2.4 Factory settings

-

Factory settings are not used.