Diagram #6 – Derale Performance Tornado Electric Fan & Thermostat Kit User Manual

Page 3

Advertising
background image

WIRING

(See Diagram #6)
1.

Disconnect the Negative (-) terminal on the vehicles battery.

2.

Using the #10 Ring Terminal & #10 x 1/2” Sheet Metal Screw

supplied, attach the

Negative (-) Electric Fan lead to

a good chassis Ground (-).

3.

Using the 14 Gauge Wire, Blue Butt Connectors & Blue Wire

Tap Connector supplied, attach one end of the wire to a
Positive (+) switched ignition source.

4.

Attach the other end of the wire to either wire on the

Thermostat Switch.

5.

Attach the remaining wire on the Thermostat Switch to

positive (+) lead on the electric fan.

6.

Reattach the Negative (-) terminal to the vehicles battery.

BLACK

Warning: Installation of accessories should only be undertaken by those with mechanical knowledge and are familiar with working on
vehicles. Always use eye protection (goggles, safety glasses or shield). Park the vehicle in a well lit area, on level ground and apply the
parking brake. Only work on a cold vehicle that has been sitting overnight, failure to do so will result in severe burns and injury. Before starting
the vehicle, make sure no tools or any other items are left under hood that could interfere with or be drawn into moving parts of the engine.
Failure to follow instructions can lead to severe damage and personal injury.

TROUBLESHOOTINTG Q&A

Q: Why Doesn’t the Electric Fan turn on?
A: 1. Check all connections to make sure all wires are crimped correctly.

2. Check all Chassis Ground (-) connections to make sure all paint is sanded off and you are getting metal to metal contact.

Q: Why is the Electric Fan blowing in the wrong direction?
A: Switch the Positive (+) and Negative (-) Electric Fan leads. This will reverse the airflow direction.

Q: Why does my fan not come on at the desired temperature?
A: Make sure the thermostat switch is located as close to the inlet on the radiator as possible if the push in probe is used. This

will allow the switch to receive the most accurate and consistent reading.