Derale Performance Adjustable Electric Fan Controller, Mechanical User Manual

Diagram #3 diagram #2 diagram #2, Diagram #1

Advertising
background image

16769-InstructionSheet

INSTALLATION INSTRUCTIONS

ADJUSTABLE THERMOSTAT SWITCH

PART # 16769

KIT CONTENTS

QTY. DESCRIPTION

1

Thermostat Switch & Probe

1

Thermostat Bracket

1

1 1/2” x 1/2” Foam Pad

2

M4-0.7 Philips Head Bolts

QTY. DESCRIPTION

2

#10 Sheet Metal Screws

1

Spool Extra Wire

1

20 Amp Fuse Holder

1

#10 Blue Ring Terminal

Please read these instructions completely before beginning installation

TOOLS NEEDED

Standard Screw Driver
Drill
5/32” Drill Bit
12V Test Light
Wire Stripper
Crimping Tool
Dyke Pliers

Derale Performance, Los Angeles, CA

800.421.6288

www.derale.com

Diagram #3

Diagram #2

Diagram #2

1 ½” x 1 ½”

Foam Pad

Radiator

Inlet Tube

Capillary

Tube

Probe

Hose Clamp

Radiator

Hose

Diagram #1

Thermostat

Switch

Capillary Tube

to Probe

M4-0.7

Philips

HeadBolts

#10 Sheet

Metal Screws

Mounting

Bracket

QTY. DESCRIPTION

1

Blue Wire Tap Connector

3

Blue Butt Connectors

2

Blue Female Connectors

4

4” Zip Ties

THERMOSTAT PROBE INSTALLATION

Making sure the vehicles engine is cold; drain enough coolant out of the radiator so the upper radiator hose can be
removed.

Coolant is a hazardous fluid, drain into container. Never open radiator cap or attempt to remove hose while

motor is hot.

1.

Remove radiator clamp and hose.

2.

Insert thermostat probe into radiator hose. (See Diagram #2)

3.

Place capillary tube on radiator inlet tube so the probe itself will remain positioned in the hose. Place the foam pad
between the capillary tube and the radiator inlet tube. (See Diagram #2)

.

Carefully install radiator hose and tighten hose clamp.

It is recommended that a screw type hose clamp is used for correct sealing (See Diagram #3). Factory type

clamps can leak.

5.

Double check coolant level, fill as required.

Warning:

4

Note:

THERMOSTAT SWITCH MOUNTING

1.

Using the two M4-0.7 Philips Head Screws, attach the Mounting Bracket to the
Thermostat Switch. (See Diagram #1)

2.

Locate the Thermostat Switch in an accessible location near the radiator inlet hose.

The Capillary Tube Probe Cannot be lengthened or cut in any way.

3.

Using the Mounting Bracket as a guide, mark and drill two 5/32” holes.

4.

Using the two #10 Sheet Metal Screws provided, attach the Thermostat Switch.

Note:

(Continues on Page 2)

Advertising