Swanstone WB-2218 - Installation User Manual

Page 17

Advertising
background image

ADA Installation Recommendations

In order to comply with ADA requirements, the lavatory must
have adequate floor clearances in front of the sink. It must
also be installed at the proper height with the specified leg and
wheel chair clearance under the sink. For complete wall
mount instructions, refer to the Wall Mount Vanity Tops and
Bowls, form number 1255.

Installing the vanity top using the supplied specifications does
not imply the bathroom in which it is installed will comply with
ADA standards. It is the responsibility of the installer/designer
to ensure that all the components of the bathroom are in
compliance with ADA standards, including the lavatory.

For complete guidelines and compliance, refer to ADA Section
606 Lavatories of the Act.

Clear Floor Space

A clear floor space, in front of the sink, for a forward approach
must be at least 30” (76.2 cm) wide and 48” (121.9 cm) long,
as shown in the illustration. These measurements are in
compliance with ADA standard 606.2.

Note: In residential bathrooms, cabinetry is permitted under

lavatory sink provided that all of the following conditions
are met:

(a) the cabinetry can be removed without removal or

replacement of the fixture;

(b) the finish floor extends under the cabinetry; and

(c) the walls behind and surrounding the cabinetry are

finished.

Accessibility Requirements

Note: Only lavatory installations in a public space must comply

with the knee and toe clearance dimensions, however we
recommend these standards be used for both private and
commercial installations. Also make sure that all state and
local building codes are followed when installing this unit.

• The top of the vanity should not exceed 34” (86.4 cm) from

the floor.

• The “knee space” below the apron of the vanity top should be

a minimum of 27” (68.6 cm) from the floor.

• The front edge of the sink should be between 17” (43.2 cm)

and 25” (63.5 cm) from the wall.

• The faucet should be a maximum of 19” (48.5 cm) from the

front of the sink.

• No part of the sink or the plumbing should be within the gray

area shown in the drawing.

ADA-LB-003a

6” (15.2 cm)

9” (22.9 cm)

8” (20.3 cm)

ADA-LB-002a

17” Minimum
25” Maximum

19” (48.5 cm)

MAX.

27”

(68.6 cm) Minim

um

34”

(86.4 cm) maxim

um

ADA-LB-001a

30”

MIN.

Clear Floor Space

48”

MIN.

19”

MAX.

IMPORTANT NOTICE

800-325-7008

17

The Swan Corporation – Swanstone

Installation Procedure

Advertising