Dexter Laundry T-80 Reversing (On-Premise) User Manual
Page 14
 
 
 
14
4-DIGIT NUMERICAL DISPLAY MESSAGES - continued 
 
 Message 
Description
 
 Prog 
This message is displayed when entering the permanent
programming
mode.
 
 .15 
This message appears while the dryer is in the heating time 
of a dry cycle. The decimal point will blink if the output 
for the gas valve is on, or remain on constantly if the output 
for the gas valve is not on. The number represents the total 
time left in the dry cycle (includes cool down time). 
 
 C02 
This message appears when the cool down time of the dry 
cycle is reached. The letter “C” represents the cool down 
(non-heating) part of the dry cycle. The number(s) after the 
letter “C” represent(s) the total time remaining in the dry 
cycle. 
 
 F5 
This message appears if there is a dryer fault. The letter 
“F” indicates a fault and the number after the “F” 
represents the specific fault that has occurred. There are 
five different faults that can appear (F1 through F5). 
 
 rEv 
This message is displayed, while in the programming mode, 
to indicate the reversing function during the dry cycle. 
 
 nrEv 
This message is displayed, while in the programming mode, 
to indicate the non-reversing function during the dry cycle.