Function test – Factory Direct Hardware Toto HDR110#SS Clean Dry User Manual
Page 6
Advertising

■
■
・
・
1.
・
2.
・
After trial run
Test the product as follows after the installation is complete.
Check the circuit breaker
Check the functionality
Turn the circuit breaker ON.
Place your hand under the outlet nozzles to see if air blows out.
After you check the functionality by trial run, give the user manual
(with warranty) to the customer, and explain how to use and maintain the
product.
First peel off the seal on the filter.
(The seal is used to protect the filter from scratches during
shipment; it is no longer needed.)
B=BLACK
R=RED
W=WHITE
Bu=BLUE
G=GREEN
Sensor
Control
Assembly
Motor
Power
Connector
Power Fuse
Motor
G
B
W
W
B
W
W
P1-1
P1-2
P3
P2
P7
P6
15A
G
Body Case
Function Test
1. Checking after installation
Wiring Diagram
Peel off the seal
Air nozzles