OSRAM ECG mountings – protection housings User Manual

OSRAM Lighting

Advertising
background image



Instruction and Safety advice for OUTKIT version 21 x 30



The housing is developed for electronic control gear (ECG) of OSRAM in a cross section of 21 x 30 mm in order
to protect the ECG reliable of humidity in IP67. OUTKIT

®

21 short is to protect 1lamp ECG in the dimension of

360 x 30 x 21 mm and OUTKIT

®

21 long to protect 2lamp ECG in the dimensions of 423 x 30 x 21 mm. OUTKIT

consists of the square pipe (1) , two screw caps, bulk enclosed seal insert for the use of single wires and 2 pcs.
caps (6).
To ensure reliable operation in IP 67 it is necessary that you follow the construction and safety information as
below:

Instruction manual:

•

To mount the cable screw you need toolings with a wrench size

15.

•

Within OUTKIT, the ECG may be mounted with single wires or special ÖLFLEX 400P from company U.I.Lapp
GmbH (

www.lappkabel.de

)

Below, please find the tested and approved types of cables and single wires:

OUTKIT 21 short

Input side

Lamp side

Wires

ÖLFLEX CLASSIC 400 P 2x0.75 for PC II or
ÖLFLEX CLASSIC 400 P 3 G 0.75 for PC I

ÖLFLEX CLASSIC
400 P 4x 0.75

Single wires

H 05 V , max. diameter of 2.3 mm
Incl. a seal insert 3x 2.3

H05 V , max. diameter of 2mm
incl. a seal insert 4x 2

OUTKIT 21 long

Input Side

Lamp Side

Wires

ÖLFLEX CLASSIC 400 P 2x0.75 for PC II or
ÖLFLEX CLASSIC 400 P 3 G 0.75 for PC I

ÖLFLEX CLASSIC
400 P 7x 0.5

Single Wires

H 05 V , max. diameter of 2.3 mm
incl. seal insert 3x 2.3

No opportunity for single wire
connection



•

For the use of dimmable ECGs you must use 2 additional wires at the input side.
ÖLFLEX CLASSIC 400 P 4x 0.75 or 400 P 5 G 0.75.

• The cover caps (6) are put from outside into the two vents at the end of the ECG and secure the positioning

of the ECG within the square pipe.

•

Press the cover caps until block of the square pipe and secure it with the tooling of the wrench size 15:


Safety instruction:

1. No guarantee for the type of protection of the system if you use different cable manufacturers.
2. If you use OUTKIT as a semiluminaire for lamps and for different light sources as well as for the use of different
ECG brands, we do not take any warranty.