background image

C> Set Up Code Length

To set the fixed length:

1. Scan the

“Begin“ label of the desired set.

2. Go to the Decimal Value Tables in Appendix A,

scan label(s) that represents the length to be
read.

3. Scan the

“Complete“ label of the desired set.

Repeat the steps 1 - 3 to set additional lengths.

<Variable>

%4 J 1 +

Fix Length (2 Sets Available)

1. 1st Set Begin

2. Decimal Value

(Appendix A)

%4J00

3. 1st Set Complete

% 4J01

1. 2nd Set Begin

2. Decimal Value

(Appendix A)

%4J00

3. 2nd Set Complete

%4J0 2

Minimum Length

1. Begin

2. Decimal Value

(Appendix A)

%2 + - /

3. Complete

% 2C5+