Multi-Station Power Supply

7

Note: ________________________________________________________________

Each DC power source should be independent of the other in order to have

power redundancy. If you do not require power redundancy, the unit can be

operated with a single power cable connected to a single DC power source.

In this case, either DC power block on the rear of the Multi-Station Power

Supply may be used for the connection.

______________________________________________________________________

Note: ________________________________________________________________

DC power cables should have a wire gauge of at least 14 and a 72VAC 13A

rating.

______________________________________________________________________

Installation in a Restricted Access Location in Finland

and Norway

Installation in a Restricted Access Location is required in Finland and Norway

for the Multi-Segment Power Supply . Because of concerns about unreli-

able earthing in Finland and Norway, this equipment must be installed in a

Restricted Access Location (RAL) in these countries. An RAL is defined as an

access that can be gained only by trained service personnel who have been in-

structed about the reasons for the restricted access and any safety precautions

that must be taken . In these cases, the use of a tool (such as lock and key) or

other means of security is required for access to this equipment .

Warnings and Symbols

Warnings on product


Two of these labels cover screws on the chassis top cover near the front

corners . They prevent you from taking the cover off without voiding

your warranty . You should not take the cover off because there are no

user-serviceable parts inside, and there is a danger of electrical shock .