GC EUROPE Fujivest Super User Manual

Page 40

Advertising
background image

40

1. Modellation

1.1 Covering the implant abutments with wax.
The layer of wax must have a sufficient

thickness to neutralise unfavourable CTE.
This is to avoid a negative effect on porcelain
firing.

1.2 Take care to not have wax all the way up

to the margin of the abutment in order to
avoid molten alloy flowing into the abutment
during casting.

1.3 Total anatomical completion of the wax

modellation, without connecting the

interproximal of the various individual

abutments / elements.

2. Stabilisation of the wax modellation (I)

2.1 Place this wax-up modellation, still on the

master model, for 30 min in a pre-heated
incubator, maintaining a temperature of
37°C.

2.2 Remove from the pre-heated incubator and

let cool down at room temperature for 1
hour.

3. Final modellation

3.1 Connect all single abutments and the wax

modellation at their interproximal contacts
using GC Pattern Resin.
- Use the brush technique for applying GC

Pattern Resin.

- Avoid using a too fluid consistency of GC

Pattern Resin in order to minimize the

polymerisation shrinkage.