Asus ESC4000/IB User Manual

Page 41

Advertising
background image

2-19

ASUS ESC4000 Series

3. Insert the PSU into the empty PSU

bay.

• If you install two power supply units in the system, you can switch the

working behavior of the two PSUs between 1+1 jumper mode and 2+0

jumper mode.

1+1 jumper mode: If the total power consumption of the system is less

than 1400W, the system can be booted using one PSU and the PSU hot-

swap feature is supported. If the total power consumption of the system

exceeds 1400W, the maximum output power of the PSUs can reach to

2800W with PSU hot-swap feature disabled, and the system shuts down if

any of the PSUs is removed.

2+0 jumper mode: The system can be booted only when two PSUs are

installed. The maximum output power of the PSUs can reach to 2800W with

PSU hot-swap feature disabled, and the system shuts down if any of the

PSUs is removed.

• The output power varies with different input voltages. Refer to the table

below for details.

SKU

Input Voltage

Max. Output Power (Watt)

1400W 100V—140V

1100W

180V—240V

1400W